Insert type Hose burst
When the lowering speed exceeds preset value, as it might happen
in case of hose failure, the flow is blocked. These valves should
ideally be screwed directly into the actuator outlet port. Sealing
parts are superfinished and enable to lock the load in the position
where the actuator is in the moment of hose failure. These valves
can be supplied, on request, with an orifice on the disc, allowing
an emergency lowering of the load. It is recommended to fit a flow
regulator valve downstream the hose burst valve, at the end of the
flexible hose, to control the lowering speed at the nominal value. The
blocking flow (flow at which the “setting” of the valve is exceeded
and that instantly actuates the valve to close) has to be calculated
multiplying the regulated flow from the actuator by a factor between
1,5 (manual directional control valve) and 2 (solenoid operated
directional control valve). This is to prevent undesired operation,
since these valves are sensitive to any transient flow above setting.
Technical data
Example
- Hydac - RBE 1/4 to 3/4
Features
- Hose burst valves for direct installation in cylinders, lines and control manifolds
- Highly reliable thanks to fast response
- Unauthorized adjustment not possible once installed
- Choice of four sizes for optimum adaptability to the system
- Different flow rate settings available as an option